Connect to PingOne Data in Claris FileMaker Pro



Use the CData ODBC Driver for PingOne in FileMaker Pro to connect to PingOne and work with PingOne data in your FileMaker applications.

Claris FileMaker is a low-code database application development tool that allows users to create custom apps for managing and organizing data. It combines a powerful relational database engine with an intuitive interface, enabling both technical and non-technical users to design and deploy applications across desktop, web, and mobile platforms.

In this article, we'll explore how to use the CData ODBC Driver for PingOne in FileMaker to connect to PingOne data.

Create an ODBC Data Source for PingOne

If you have not already, first specify connection properties in an ODBC DSN (data source name). This is the last step of the driver installation. You can use the Microsoft ODBC Data Source Administrator to create and configure ODBC DSNs.

To connect to PingOne, configure these properties:

  • Region: The region where the data for your PingOne organization is being hosted.
  • AuthScheme: The type of authentication to use when connecting to PingOne.
  • Either WorkerAppEnvironmentId (required when using the default PingOne domain) or AuthorizationServerURL, configured as described below.

Configuring WorkerAppEnvironmentId

WorkerAppEnvironmentId is the ID of the PingOne environment in which your Worker application resides. This parameter is used only when the environment is using the default PingOne domain (auth.pingone). It is configured after you have created the custom OAuth application you will use to authenticate to PingOne, as described in Creating a Custom OAuth Application in the Help documentation.

First, find the value for this property:

  1. From the home page of your PingOne organization, move to the navigation sidebar and click Environments.
  2. Find the environment in which you have created your custom OAuth/Worker application (usually Administrators), and click Manage Environment. The environment's home page displays.
  3. In the environment's home page navigation sidebar, click Applications.
  4. Find your OAuth or Worker application details in the list.
  5. Copy the value in the Environment ID field. It should look similar to:
    WorkerAppEnvironmentId='11e96fc7-aa4d-4a60-8196-9acf91424eca'

Now set WorkerAppEnvironmentId to the value of the Environment ID field.

Configuring AuthorizationServerURL

AuthorizationServerURL is the base URL of the PingOne authorization server for the environment where your application is located. This property is only used when you have set up a custom domain for the environment, as described in the PingOne platform API documentation. See Custom Domains.

Authenticating to PingOne with OAuth

PingOne supports both OAuth and OAuthClient authentication. In addition to performing the configuration steps described above, there are two more steps to complete to support OAuth or OAuthCliet authentication:

  • Create and configure a custom OAuth application, as described in Creating a Custom OAuth Application in the Help documentation.
  • To ensure that the driver can access the entities in Data Model, confirm that you have configured the correct roles for the admin user/worker application you will be using, as described in Administrator Roles in the Help documentation.
  • Set the appropriate properties for the authscheme and authflow of your choice, as described in the following subsections.

OAuth (Authorization Code grant)

Set AuthScheme to OAuth.

Desktop Applications

Get and Refresh the OAuth Access Token

After setting the following, you are ready to connect:

  • InitiateOAuth: GETANDREFRESH. To avoid the need to repeat the OAuth exchange and manually setting the OAuthAccessToken each time you connect, use InitiateOAuth.
  • OAuthClientId: The Client ID you obtained when you created your custom OAuth application.
  • OAuthClientSecret: The Client Secret you obtained when you created your custom OAuth application.
  • CallbackURL: The redirect URI you defined when you registered your custom OAuth application. For example: https://localhost:3333

When you connect, the driver opens PingOne's OAuth endpoint in your default browser. Log in and grant permissions to the application. The driver then completes the OAuth process:

  1. The driver obtains an access token from PingOne and uses it to request data.
  2. The OAuth values are saved in the location specified in OAuthSettingsLocation, to be persisted across connections.

The driver refreshes the access token automatically when it expires.

For other OAuth methods, including Web Applications, Headless Machines, or Client Credentials Grant, refer to the Help documentation.

When you configure the DSN, you may also want to set the Max Rows connection property. This will limit the number of rows returned, which is especially helpful for improving performance when designing reports and visualizations.

Connect and sync PingOne data with FileMaker using the CData ODBC Driver for PingOne

Once you configure the CData ODBC Driver for PingOne, you can connect to live PingOne data in FileMaker and use it in your applications. In this section, we'll walk through the steps to connect live PingOne data to FileMaker.

You can download and install the latest version of FileMaker Pro for your Mac/Windows/Linux systems here: https://www.claris.com/resources/downloads/.

Importing PingOne data using FileMaker's ODBC Import Function

Follow the steps below to easily import PingOne data using the ODBC import feature:

  1. Open FileMaker Pro. Navigate to Create from the left panel and select Blank > Create.
  2. Enter a desired filename and click Save.
  3. In the Manage Database window, go to the Tables tab and create or rename the table where you want to display PingOne data.
  4. In the Fields tab, add the required fields to the table.
  5. In the Relationships tab, define table relationships if your database has multiple tables, then click OK.
  6. To reopen and modify the table structure later, go to File > Manage > Database.
  7. To import PingOne data via the CData ODBC Driver for PingOne, navigate to File > Import Records > ODBC Data Source.
  8. In the Select ODBC Data Source window, choose CData ODBC Driver for PingOne and click Create. Enter your PingOne username and password, then click OK.
  9. In the SQL Query Builder window, select the desired table from the Tables section and choose the relevant columns from the Columns section. Click Insert into SQL Query after each selection to automatically generate a query that retrieves data from PingOne. You can also manually edit the query using WHERE and ORDER BY clauses or use the tabs provided in the SQL Query Builder. Click Execute to run the query.
  10. In the Specify Import Order window, define the import order for the target fields. Select Add between source and target to add new records to the target table from the selected fields. Click Import.

You have now successfully imported PingOne data into FileMaker Pro using the CData ODBC Driver for PingOne. To perform incremental updates, change the import order to "Update" or use "Replace" based on your use case.

Process PingOne data at design time

You can sort and aggregate data, as well as calculate summary functions while browsing tables. To manipulate the view of data at design time, complete the following steps:

  • Switch to Preview Mode: Click the Preview at the top to check how the PingOne data with look before you print it.
  • Switch to Table View: Click the table icon in the View As menu in the main toolbar of the application.

Aggregate and summarize

Follow the steps below to group column values and display summaries, as shown in the screenshot:

  • Sort: Click the arrow in the NumberOfEmployees column header and choose Sort Ascending from the menu.
  • Group: In the same menu, click Add Trailing Group by Industry to group the values and insert a summary row. Alternatively, click Add Leading Group to add a summary row at the beginning.
  • Summarize: Select a summary option from the Trailing Subtotals menu for a grouped column.

Create a bar chart

Use the following steps to create a simple bar chart showing the total NumberOfEmployees for each Industry:

  1. Click the arrow in the NumberOfEmployees column header and select Chart by NumberOfEmployees.
    • If you've already grouped the table by a column (e.g., Industry), you can chart NumberOfEmployees by that column.
  2. In the Chart Setup window:
    • Click the button next to the Data box to add the x-axis column.
    • Choose the appropriate column in the dialog that appears.
    • For the y-axis, select a summary option from the Summary menu.

Get Started Today

Download a free 30-day trial of the CData ODBC Driver for PingOne to integrate PingOne data into Claris FileMaker and work with PingOne data in your FileMaker applications.

Reach out to our Support Team if you have any questions.

Ready to get started?

Download a free trial of the PingOne ODBC Driver to get started:

 Download Now

Learn more:

PingOne Icon PingOne ODBC Driver

The PingOne ODBC Driver is a powerful tool that allows you to connect with live data from PingOne, directly from any applications that support ODBC connectivity.

Access PingOne data like you would a database - read, write, and update PingOne 0, etc. through a standard ODBC Driver interface.